Dry Type Cast Resin Transformer
Dry Type Cast Resin Transformer

Dry Type Cast Resin Transformer

MOQ : 1 Unit

Dry Type Cast Resin Transformer Specification

  • High Voltage
  • Up to 33 kV
  • Dimension (L*W*H)
  • Varies with rating, typically 1800mm x 1000mm x 1600mm (for 1000 kVA)
  • Rated Voltage
  • Up to 33 kV
  • Cooling Type
  • AN (Air Natural)/AF (Air Forced)
  • Low Voltage
  • 0.4 kV, 0.415 kV
  • Coil Material
  • Copper or Aluminum
  • Capacity
  • 100 kVA to 2500 kVA
  • Load Loss
  • As per IS 1180 standards
  • Standard
  • IS 11171 / IEC 60076-11
  • Voltage Booster Type
  • Step-up/Step-down
  • Operating Temperature
  • -25C to +50C
  • Product Type
  • Dry Type Cast Resin Transformer
  • Material
  • Copper/Aluminum windings, resin cast insulation
  • Output
  • As per application, commonly 415V
  • Frequency (MHz)
  • 50/60 Hz
  • Efficiency
  • Up to 98%
  • Phase
  • Three Phase
  • Usage
  • Industrial power distribution, sensitive locations such as hospitals, commercial complexes, and high-rise buildings.
  • Coil Structure
  • Encapsulated resin cast coil
  • Coil Number
  • Three
  • Power Scope
  • 100 kVA to 2500 kVA
  • Weight
  • Depends on rating; for 1000 kVA approximately 2600 kg
  • Insulation Class
  • Class F or H
  • Cooling Fan Provision
  • Available for AF models
  • Mounting Type
  • Floor-mounted with rollers or skids
  • Temperature Rise
  • Maximum 100K for winding, 70K for core
  • Thermal Protection
  • PT100 sensors in windings
  • Tap Changer
  • Off-circuit tap links / On-load tap changer (optional)
  • Protection Class
  • IP23
  • Short Circuit Impedance
  • 4% to 6% (as per rating)
  • Altitude Suitability
  • Up to 1000 meters without de-rating
  • Partial Discharge
  • Less than 10 pC at 1.1 x rated voltage
  • Maintenance
  • Virtually maintenance-free
  • Humidity Tolerance
  • Up to 100% RH
  • Fire Resistance
  • Self-extinguishing epoxy resin
  • Connection Type
  • Dyn11, Yyn0, or as per requirements
  • Noise Level
  • Less than 65 dB
  • Earthquake Resistance
  • Available with seismic qualification on request
 

Dry Type Cast Resin Transformer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 5-7
  • Main Domestic Market
  • All India
 

About Dry Type Cast Resin Transformer



Jump on the opportunity to own this acclaimed Dry Type Cast Resin Transformer engineered for sublime performance and glorious reliability. Crafted with self-extinguishing epoxy resin, this transformer is the go-to solution for sensitive locations such as hospitals, commercial complexes, and high-rise buildings. With ultra-quiet operation (less than 65 dB), a transcendent efficiency of up to 98%, and supreme protection (IP23), you enjoy the best price for maximum functionality. Fire-resistant, maintenance-free, and equipped for altitudes up to 1000 meters, it's perfect for industrial power distribution and critical applications.

Versatile Application Areas & Surface Suitability

The Dry Type Cast Resin Transformer shines across a diverse range of application surfaces and media. Ideal for floor-mounted setups using rollers or skids, it adapts effortlessly to industrial plants, data centers, commercial complexes, and hospital environments. Its humidity tolerance up to 100% RH confirms its resilience in challenging application media, ensuring smooth operations in both interior and semi-open installations. This versatility makes it a sublime fit for areas with stringent safety and performance requirements.


Certifications, Distribution & Sample Availability

Certified to IS 11171 and IEC 60076-11 standards, this transformer meets the highest quality benchmarks for the Indian market. Main domestic markets span across India, supported by prompt shipped goods, hassle-free drop-off, and secure packaging. Samples are available on request to facilitate selection before final purchase. Each transformer arrives protected for transit, ensuring that every unit reaches your site in optimal condition, ready for seamless installation and immediate operation.


FAQ's of Dry Type Cast Resin Transformer:


Q: How does this Dry Type Cast Resin Transformer manage high humidity environments?

A: The transformer is designed to tolerate up to 100% relative humidity, making it ideal for locations where moisture resistance is essential, such as hospitals and coastal installations.

Q: What are the main benefits of choosing this transformer over oil-filled variants?

A: Key benefits include self-extinguishing epoxy resin insulation, virtually maintenance-free operation, low noise levels, improved safety, and root resilience in areas sensitive to fire hazards-all without requiring oil.

Q: Where can this transformer be installed safely?

A: It can be floor-mounted in industrial facilities, commercial buildings, hospitals, and high-rise complexes, with mounting options including rollers or skids for flexibility based on space and load.

Q: What certifications does the transformer carry?

A: The product is tested and certified according to IS 11171 and IEC 60076-11 standards, assuring you of its quality and reliability.

Q: How are units shipped and can samples be obtained?

A: Transformers are delivered securely packaged via reliable shipped goods or direct drop-off; samples are available upon request for pre-installation evaluation.

Q: What is the maintenance process for this unit?

A: Thanks to encapsulated resin cast coils and self-monitoring PT100 sensors, the transformer requires minimal maintenance, primarily routine inspections and system checks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top